Higher yields | Safe & Reliable | Smart | User-friendly
Three Phase String Inverter
HPI-15/17K-G03 | 15-17KW | Three Phase | 2 MPPT
The series products adopt 2 MPP trackers design. Equipped with screw crimp terminal for DC and AC side, convenient installation and maintenance. With high detection accuracy, when the load power is less than 2%, the measurement accuracy is still high. In addition, it allows the system to be monitored and controlled remotely.
Technical Specifications
HPI-15K-G03
HPI-17K-G03
HPI-15K-G03
| Model | HPI-15K-G03 | HPI-17K-G03 |
| Input Side | ||
| Max. DC Input Power(kW) | 19.5 | 22.1 |
| Max. DC Input Voltage (V) | 1000 | |
| Start-up DC Input Voltage(V) | 250 | |
| MPPT Operating Range(V) | 200~850 | |
| Max. DC Input Current(A) | 13+26 | |
| Max. Short Circuit Current (A) | 19.5+39 | |
| Number of MPPT/Strings per MPPT | 2 / 1+2 | |
| Output Side | ||
| Rated Output Power(kW) | 15 | 17 |
| Max. Active Power(kW) | 16.5 | 18.7 |
| Rated AC Grid Voltage(V) | 220/ 380,230/ 400 | |
| AC Grid Voltage Range(V) | 277Vac~460Vac(this may vary with grid standards) | |
| Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |
| Operating Phase | Three phase | |
| Rated AC Grid Output Current(A) | 21.8 | 24.6 |
| Max. AC Output Current(A) | 23.9 | 27.1 |
| Output Power Factor | 0.8 leading to 0.8 lagging | |
| Grid Current THD | <3% | |
| DC Injection Current(mA) | <0.5% | |
| Grid Frequency Range | 47~52 or 57~62 (Optional) | |
| Efficiency | |
| Max.Efficiency | 98.5% |
| Euro Efficiency | 97.5% |
| MPPT Efficiency | >99% |
| Protection | ||
| DC Reverse-Polarity Protection | Yes | |
| AC Short Circuit Protection | Yes | |
| AC Output Overcurrent Protection | Yes | |
| Output Overvoltage Protection | Yes | |
| Insulation Resistance Protection | Yes | |
| Ground Fault Monitoring | Yes | |
| Islanding Protection | Yes | |
| Temperature Protection | Yes | |
| Integrated DC Switch | Yes | |
| Remote software upload | Yes | |
| Remote change of operating parameters | Yes | |
| Surge protection | DC Type II / AC Type II | |
| General Data | |
| Size(mm) | 330W×472H×202D |
| Weight(kg) | 15 |
| Topology | Transformerless |
| Internal Consumption | <1W(Night) |
| Running Temperature | -25~65℃ |
| Ingress Protection | IP65 |
| Noise Emission(Typical) | <40dB |
| Cooling Concept | Natural cooling |
| Max. Operating Altitude Without Derating | 2000m |
| Designed Lifetime | >20years |
| Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 |
| Operating Surroundings Humidity | 0-100% |
| Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
| Features | |
| DC Connection | MC-4 mateable |
| AC Connection | IP65 rated plug |
| Display | LCD1602 |
| Interface | RS485/RS232/Wifi/LAN |
HPI-17K-G03
| Model | HPI-15K-G03 | HPI-17K-G03 |
| Input Side | ||
| Max. DC Input Power(kW) | 19.5 | 22.1 |
| Max. DC Input Voltage (V) | 1000 | |
| Start-up DC Input Voltage(V) | 250 | |
| MPPT Operating Range(V) | 200~850 | |
| Max. DC Input Current(A) | 13+26 | |
| Max. Short Circuit Current (A) | 19.5+39 | |
| Number of MPPT/Strings per MPPT | 2 / 1+2 | |
| Output Side | ||
| Rated Output Power(kW) | 15 | 17 |
| Max. Active Power(kW) | 16.5 | 18.7 |
| Rated AC Grid Voltage(V) | 220/ 380,230/ 400 | |
| AC Grid Voltage Range(V) | 277Vac~460Vac(this may vary with grid standards) | |
| Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |
| Operating Phase | Three phase | |
| Rated AC Grid Output Current(A) | 21.8 | 24.6 |
| Max. AC Output Current(A) | 23.9 | 27.1 |
| Output Power Factor | 0.8 leading to 0.8 lagging | |
| Grid Current THD | <3% | |
| DC Injection Current(mA) | <0.5% | |
| Grid Frequency Range | 47~52 or 57~62 (Optional) | |
| Efficiency | |
| Max.Efficiency | 98.5% |
| Euro Efficiency | 97.5% |
| MPPT Efficiency | >99% |
| Protection | ||
| DC Reverse-Polarity Protection | Yes | |
| AC Short Circuit Protection | Yes | |
| AC Output Overcurrent Protection | Yes | |
| Output Overvoltage Protection | Yes | |
| Insulation Resistance Protection | Yes | |
| Ground Fault Monitoring | Yes | |
| Islanding Protection | Yes | |
| Temperature Protection | Yes | |
| Integrated DC Switch | Yes | |
| Remote software upload | Yes | |
| Remote change of operating parameters | Yes | |
| Surge protection | DC Type II / AC Type II | |
| General Data | |
| Size(mm) | 330W×472H×202D |
| Weight(kg) | 15 |
| Topology | Transformerless |
| Internal Consumption | <1W(Night) |
| Running Temperature | -25~65℃ |
| Ingress Protection | IP65 |
| Noise Emission(Typical) | <40dB |
| Cooling Concept | Natural cooling |
| Max. Operating Altitude Without Derating | 2000m |
| Designed Lifetime | >20years |
| Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 |
| Operating Surroundings Humidity | 0-100% |
| Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
| Features | |
| DC Connection | MC-4 mateable |
| AC Connection | IP65 rated plug |
| Display | LCD1602 |
| Interface | RS485/RS232/Wifi/LAN |