- 127/220Vac and 60Hz, three phase system
- 2 MPP tracker, Max. efficiency up to 98.5%
- Zero export application, VSG application
- String intelligent monitoring (optional)
- Wide output voltage range
- Anti-PID function (Optional)
Technical Specifications
HPI-6K-G03-LV
HPI-8K-G03-LV
HPI-6K-G03-LV
Model | HPI-6K-G03-LV | HPI-8K-G03-LV | |
Input Side | |||
Max. DC Input Power(kW) | 7.8 | 10.4 | |
Max. DC Input Voltage (V) | 800 | ||
Start-up DC Input Voltage(V) | 250 | ||
MPPT Operating Range(V) | 200~700 | ||
Max. DC Input Current(A) | 13+13 | 13+26 | |
Max. Short Circuit Current (A) | 19.5+19.5 | 19.5+39 | |
Number of MPPT/Strings per MPPT | 2 / 1 | 2 / 1+2 |
Output Side |
||
Rated Output Power(kW) | 6 | 8 |
Max. Active Power(kW) | 6.6 | 8.8 |
Rated AC Grid Voltage(V) | 127 / 220 | |
AC Grid Voltage Range(V) | 176Vac~242Vac(this may vary with grid standards) | |
Rated Grid Frequency(Hz) | 60 / 50 (Optional) | |
Operating Phase | Three phase | |
Rated AC Grid Output Current(A) | 15.7 | 21 |
Max. AC Output Current(A) | 17.3 | 23.1 |
Output Power Factor | 0.8 leading to 0.8 lagging | |
Grid Current THD | <3% | |
DC Injection Current(mA) | <0.5% | |
Grid Frequency Range | 47~52 or 57~62 (Optional) |
Efficiency | ||
Max.Efficiency | 98.3% | 98.5% |
Euro Efficiency | 97.5% | |
MPPT Efficiency | >99% |
Protection | ||
DC Reverse-Polarity Protection | Yes | |
AC Short Circuit Protection | Yes | |
AC Output Overcurrent Protection | Yes | |
Output Overvoltage Protection | Yes | |
Insulation Resistance Protection | Yes | |
Ground Fault Monitoring | Yes | |
Islanding Protection | Yes | |
Temperature Protection | Yes | |
Integrated DC Switch | Yes | |
Remote software upload | Yes | |
Remote change of operating parameters | Yes | |
Surge protection | DC Type II / AC Type II |
General Data | ||
Size(mm) | 330W×457.5H×185D | 330W×472H×202D |
Weight(kg) | 10 | 15 |
Topology | Transformerless | |
Internal Consumption | <1W(Night) | |
Running Temperature | -25~65℃ | |
Ingress Protection | IP65 | |
Noise Emission(Typical) | <25dB | <45dB |
Cooling Concept | Smart cooling | |
Max. Operating Altitude Without Derating | 2000m | |
Designed Lifetime | >20years | |
Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 | |
Operating Surroundings Humidity | 0-100% | |
Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
Features | |
DC Connection | MC-4 mateable |
AC Connection | IP65 rated plug |
Display | LCD1602 |
Interface | RS485/RS232/Wifi/LAN |
HPI-8K-G03-LV
Model | HPI-6K-G03-LV | HPI-8K-G03-LV | |
Input Side | |||
Max. DC Input Power(kW) | 7.8 | 10.4 | |
Max. DC Input Voltage (V) | 800 | ||
Start-up DC Input Voltage(V) | 250 | ||
MPPT Operating Range(V) | 200~700 | ||
Max. DC Input Current(A) | 13+13 | 13+26 | |
Max. Short Circuit Current (A) | 19.5+19.5 | 19.5+39 | |
Number of MPPT/Strings per MPPT | 2 / 1 | 2 / 1+2 |
Output Side |
||
Rated Output Power(kW) | 6 | 8 |
Max. Active Power(kW) | 6.6 | 8.8 |
Rated AC Grid Voltage(V) | 127 / 220 | |
AC Grid Voltage Range(V) | 176Vac~242Vac(this may vary with grid standards) | |
Rated Grid Frequency(Hz) | 60 / 50 (Optional) | |
Operating Phase | Three phase | |
Rated AC Grid Output Current(A) | 15.7 | 21 |
Max. AC Output Current(A) | 17.3 | 23.1 |
Output Power Factor | 0.8 leading to 0.8 lagging | |
Grid Current THD | <3% | |
DC Injection Current(mA) | <0.5% | |
Grid Frequency Range | 47~52 or 57~62 (Optional) |
Efficiency | ||
Max.Efficiency | 98.3% | 98.5% |
Euro Efficiency | 97.5% | |
MPPT Efficiency | >99% |
Protection | ||
DC Reverse-Polarity Protection | Yes | |
AC Short Circuit Protection | Yes | |
AC Output Overcurrent Protection | Yes | |
Output Overvoltage Protection | Yes | |
Insulation Resistance Protection | Yes | |
Ground Fault Monitoring | Yes | |
Islanding Protection | Yes | |
Temperature Protection | Yes | |
Integrated DC Switch | Yes | |
Remote software upload | Yes | |
Remote change of operating parameters | Yes | |
Surge protection | DC Type II / AC Type II |
General Data | ||
Size(mm) | 330W×457.5H×185D | 330W×472H×202D |
Weight(kg) | 10 | 15 |
Topology | Transformerless | |
Internal Consumption | <1W(Night) | |
Running Temperature | -25~65℃ | |
Ingress Protection | IP65 | |
Noise Emission(Typical) | <25dB | <45dB |
Cooling Concept | Smart cooling | |
Max. Operating Altitude Without Derating | 2000m | |
Designed Lifetime | >20years | |
Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 | |
Operating Surroundings Humidity | 0-100% | |
Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
Features | |
DC Connection | MC-4 mateable |
AC Connection | IP65 rated plug |
Display | LCD1602 |
Interface | RS485/RS232/Wifi/LAN |