Higher yields | Safe & Reliable | Smart | User-friendly
Three Phase String Inverter
HPI-60/70/75/80K-G | 60-80KW | Three Phase | 4 MPPT
The HPI 60-80K grid-connected inverter is suited for medium and large-scale commercial rooftops and ground-mounted solar PV system in which reliability and stability are important. the full series inverter has 30% DC input oversizing ratio and 10% AC output overloading ratio, offering a faster return on investment.
Technical Specifications
HPI-60K-G
HPI-70K-G
HPI-75K-G
HPI-80K-G
HPI-60K-G
Model | HPI-60K-G | HPI-70K-G | HPI-75K-G | HPI-80K-G |
Input Side | ||||
Max. DC Input Power(kW) | 78 | 91 | 97.5 | 104 |
Max. DC Input Voltage (V) | 1000 | |||
Start-up DC Input Voltage(V) | 250 | |||
MPPT Operating Range(V) | 200~850 | |||
Max. DC Input Current(A) | 40+40+40+40 | |||
Max. Short Circuit Current (A) | 60+60+60+60 | |||
Number of MPPT/Strings per MPPT | 4/3 | 4/4 | 4/4 | 4/4 |
Output Side | ||||
Rated Output Power(kW) | 60 | 70 | 75 | 80 |
Max. Active Power(kW) | 66 | 77 | 82.5 | 88 |
Rated AC Grid Voltage(V) | 230 / 400 | |||
AC Grid Voltage Range(V) | 277Vac~460Vac(this may vary with grid standards) | |||
Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |||
Operating Phase | Three phase | |||
Rated AC Grid Output Current(A) | 87.8 | 101.5 | 108.7 | 115.9 |
Max. AC Output Current(A) | 95.7 | 111.6 | 119.6 | 127.5 |
Output Power Factor | 0.8 leading to 0.8 lagging | |||
Grid Current THD | <3% | |||
DC Injection Current(mA) | <0.5% | |||
Grid Frequency Range | 47~52 or 57~62 (Optional) |
Efficiency | |
Max.Efficiency | 98.7% |
Euro Efficiency | 98.7% |
MPPT Efficiency | >99% |
Protection | ||
DC Reverse-Polarity Protection | Yes | |
AC Short Circuit Protection | Yes | |
AC Output Overcurrent Protection | Yes | |
Output Overvoltage Protection | Yes | |
Insulation Resistance Protection | Yes | |
Ground Fault Monitoring | Yes | |
Islanding Protection | Yes | |
Temperature Protection | Yes | |
Integrated DC Switch | Yes | |
Remote software upload | Yes | |
Remote change of operating parameters | Yes | |
Surge protection | DC Type II / AC Type II |
General Data | |
Size(mm) | 700W×575H×297D |
Weight(kg) | 60 |
Topology | Transformerless |
Internal Consumption | <1W(Night) |
Running Temperature | -25~65℃ |
Ingress Protection | IP65 |
Noise Emission(Typical) | <55 dB |
Cooling Concept | Smart cooling |
Max. Operating Altitude Without Derating | 2000m |
Designed Lifetime | >20years |
Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 |
Operating Surroundings Humidity | 0-100% |
Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
Features | |
DC Connection | MC-4 mateable |
AC Connection | IP65 rated plug |
Display | LCD 240 × 160 |
Interface | RS485/RS232/Wifi/LAN |
HPI-70K-G
Model | HPI-60K-G | HPI-70K-G | HPI-75K-G | HPI-80K-G |
Input Side | ||||
Max. DC Input Power(kW) | 78 | 91 | 97.5 | 104 |
Max. DC Input Voltage (V) | 1000 | |||
Start-up DC Input Voltage(V) | 250 | |||
MPPT Operating Range(V) | 200~850 | |||
Max. DC Input Current(A) | 40+40+40+40 | |||
Max. Short Circuit Current (A) | 60+60+60+60 | |||
Number of MPPT/Strings per MPPT | 4/3 | 4/4 | 4/4 | 4/4 |
Output Side | ||||
Rated Output Power(kW) | 60 | 70 | 75 | 80 |
Max. Active Power(kW) | 66 | 77 | 82.5 | 88 |
Rated AC Grid Voltage(V) | 230 / 400 | |||
AC Grid Voltage Range(V) | 277Vac~460Vac(this may vary with grid standards) | |||
Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |||
Operating Phase | Three phase | |||
Rated AC Grid Output Current(A) | 87.8 | 101.5 | 108.7 | 115.9 |
Max. AC Output Current(A) | 95.7 | 111.6 | 119.6 | 127.5 |
Output Power Factor | 0.8 leading to 0.8 lagging | |||
Grid Current THD | <3% | |||
DC Injection Current(mA) | <0.5% | |||
Grid Frequency Range | 47~52 or 57~62 (Optional) |
Efficiency | |
Max.Efficiency | 98.7% |
Euro Efficiency | 98.7% |
MPPT Efficiency | >99% |
Protection | ||
DC Reverse-Polarity Protection | Yes | |
AC Short Circuit Protection | Yes | |
AC Output Overcurrent Protection | Yes | |
Output Overvoltage Protection | Yes | |
Insulation Resistance Protection | Yes | |
Ground Fault Monitoring | Yes | |
Islanding Protection | Yes | |
Temperature Protection | Yes | |
Integrated DC Switch | Yes | |
Remote software upload | Yes | |
Remote change of operating parameters | Yes | |
Surge protection | DC Type II / AC Type II |
General Data | |
Size(mm) | 700W×575H×297D |
Weight(kg) | 60 |
Topology | Transformerless |
Internal Consumption | <1W(Night) |
Running Temperature | -25~65℃ |
Ingress Protection | IP65 |
Noise Emission(Typical) | <55 dB |
Cooling Concept | Smart cooling |
Max. Operating Altitude Without Derating | 2000m |
Designed Lifetime | >20years |
Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 |
Operating Surroundings Humidity | 0-100% |
Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
Features | |
DC Connection | MC-4 mateable |
AC Connection | IP65 rated plug |
Display | LCD 240 × 160 |
Interface | RS485/RS232/Wifi/LAN |
HPI-75K-G
Model | HPI-60K-G | HPI-70K-G | HPI-75K-G | HPI-80K-G |
Input Side | ||||
Max. DC Input Power(kW) | 78 | 91 | 97.5 | 104 |
Max. DC Input Voltage (V) | 1000 | |||
Start-up DC Input Voltage(V) | 250 | |||
MPPT Operating Range(V) | 200~850 | |||
Max. DC Input Current(A) | 40+40+40+40 | |||
Max. Short Circuit Current (A) | 60+60+60+60 | |||
Number of MPPT/Strings per MPPT | 4/3 | 4/4 | 4/4 | 4/4 |
Output Side | ||||
Rated Output Power(kW) | 60 | 70 | 75 | 80 |
Max. Active Power(kW) | 66 | 77 | 82.5 | 88 |
Rated AC Grid Voltage(V) | 230 / 400 | |||
AC Grid Voltage Range(V) | 277Vac~460Vac(this may vary with grid standards) | |||
Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |||
Operating Phase | Three phase | |||
Rated AC Grid Output Current(A) | 87.8 | 101.5 | 108.7 | 115.9 |
Max. AC Output Current(A) | 95.7 | 111.6 | 119.6 | 127.5 |
Output Power Factor | 0.8 leading to 0.8 lagging | |||
Grid Current THD | <3% | |||
DC Injection Current(mA) | <0.5% | |||
Grid Frequency Range | 47~52 or 57~62 (Optional) |
Efficiency | |
Max.Efficiency | 98.7% |
Euro Efficiency | 98.7% |
MPPT Efficiency | >99% |
Protection | ||
DC Reverse-Polarity Protection | Yes | |
AC Short Circuit Protection | Yes | |
AC Output Overcurrent Protection | Yes | |
Output Overvoltage Protection | Yes | |
Insulation Resistance Protection | Yes | |
Ground Fault Monitoring | Yes | |
Islanding Protection | Yes | |
Temperature Protection | Yes | |
Integrated DC Switch | Yes | |
Remote software upload | Yes | |
Remote change of operating parameters | Yes | |
Surge protection | DC Type II / AC Type II |
General Data | |
Size(mm) | 700W×575H×297D |
Weight(kg) | 60 |
Topology | Transformerless |
Internal Consumption | <1W(Night) |
Running Temperature | -25~65℃ |
Ingress Protection | IP65 |
Noise Emission(Typical) | <55 dB |
Cooling Concept | Smart cooling |
Max. Operating Altitude Without Derating | 2000m |
Designed Lifetime | >20years |
Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 |
Operating Surroundings Humidity | 0-100% |
Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
Features | |
DC Connection | MC-4 mateable |
AC Connection | IP65 rated plug |
Display | LCD 240 × 160 |
Interface | RS485/RS232/Wifi/LAN |
HPI-80K-G
Model | HPI-60K-G | HPI-70K-G | HPI-75K-G | HPI-80K-G |
Input Side | ||||
Max. DC Input Power(kW) | 78 | 91 | 97.5 | 104 |
Max. DC Input Voltage (V) | 1000 | |||
Start-up DC Input Voltage(V) | 250 | |||
MPPT Operating Range(V) | 200~850 | |||
Max. DC Input Current(A) | 40+40+40+40 | |||
Max. Short Circuit Current (A) | 60+60+60+60 | |||
Number of MPPT/Strings per MPPT | 4/3 | 4/4 | 4/4 | 4/4 |
Output Side | ||||
Rated Output Power(kW) | 60 | 70 | 75 | 80 |
Max. Active Power(kW) | 66 | 77 | 82.5 | 88 |
Rated AC Grid Voltage(V) | 230 / 400 | |||
AC Grid Voltage Range(V) | 277Vac~460Vac(this may vary with grid standards) | |||
Rated Grid Frequency(Hz) | 50 / 60 (Optional) | |||
Operating Phase | Three phase | |||
Rated AC Grid Output Current(A) | 87.8 | 101.5 | 108.7 | 115.9 |
Max. AC Output Current(A) | 95.7 | 111.6 | 119.6 | 127.5 |
Output Power Factor | 0.8 leading to 0.8 lagging | |||
Grid Current THD | <3% | |||
DC Injection Current(mA) | <0.5% | |||
Grid Frequency Range | 47~52 or 57~62 (Optional) |
Efficiency | |
Max.Efficiency | 98.7% |
Euro Efficiency | 98.7% |
MPPT Efficiency | >99% |
Protection | ||
DC Reverse-Polarity Protection | Yes | |
AC Short Circuit Protection | Yes | |
AC Output Overcurrent Protection | Yes | |
Output Overvoltage Protection | Yes | |
Insulation Resistance Protection | Yes | |
Ground Fault Monitoring | Yes | |
Islanding Protection | Yes | |
Temperature Protection | Yes | |
Integrated DC Switch | Yes | |
Remote software upload | Yes | |
Remote change of operating parameters | Yes | |
Surge protection | DC Type II / AC Type II |
General Data | |
Size(mm) | 700W×575H×297D |
Weight(kg) | 60 |
Topology | Transformerless |
Internal Consumption | <1W(Night) |
Running Temperature | -25~65℃ |
Ingress Protection | IP65 |
Noise Emission(Typical) | <55 dB |
Cooling Concept | Smart cooling |
Max. Operating Altitude Without Derating | 2000m |
Designed Lifetime | >20years |
Grid Connection Standard | EN50549, IEC61727, VDE 0126-1-1, IEC62109-1-2 |
Operating Surroundings Humidity | 0-100% |
Safety EMC/Standard | IEC62109-1/-2, EN61000-6-1, EN61000-6-3 |
Features | |
DC Connection | MC-4 mateable |
AC Connection | IP65 rated plug |
Display | LCD 240 × 160 |
Interface | RS485/RS232/Wifi/LAN |